- 42 - FC-RIDERS-V2-OP-EN v22.235
Error Internal Label Code Type Description Action Remedy
Vacuum motor current
over software limit
VACUUM_SOFTWARE_OV
49
soft The vacuum motor current has
exceed the software limit
The vacuum motor is
disabled
Squeegee motor
current over hardware
limit
SQUEE_HARDWARE_OV
50
soft The squeegee motor current has
exceed the absolute hardware
limit
The squeegee actuator is
disabled
VALVE_FAULT
51
Open circuit detected
in vacuum motor
VACUUM_OPEN_CIRCUIT
52
soft An electrically open condition
has been detected in the vacuum
motor circuit
The vacuum motor is
disabled
TRACT_RIGHT_NULL_ERROR
53
TRACTION_OPEN_CIRCUIT
54
Open circuit detected
in deck actuator
BRUSH_DECK_OPEN_CIRCUIT
55
soft An electrically open condition
has been detected in the deck
actuator circuit
Brush, deck actuator and
water/suds are disabled
TRAIL_TIME_OUT
56
SOLENOID_WELDED_OTHER
57
SOLENOID_CLOSE_LIM-
IT_WARNING
58
Squeegee motor
stalled
SQUEE_STALLED_MOTOR 59 soft An energized squeegee actuator
is not moving
The squeegee actuator is
disabled
Deck actuator stalled BRU_DECK_STALLED_MOTOR 60 soft An energized deck actuator is not
rotating
Brush, deck actuator and
water/suds are disabled
PRECHARGE_FAILURE_OTHER 61
Brush motor stalled BRUSH_STALLED_MOTOR 62 soft An energized brush motor is not
rotating
Brush, deck actuator and
water/suds are disabled
vacuum motor stalled VACUUM_STALLED_MOTOR 63 soft An energized vacuum motor is
not rotating
The vacuum motor is
disabled
LEFT_CURRENT_LIMIT 64
RIGHT_CURRENT_LIMIT 65
Overheat MOSFET THERMAL_CUTBACK_MOS 66 hard The transport motor drive circuit
has had an over temperature
failure
The machine is disabled
Battery over voltage HIGH_BATTERY_PROTECT 67 hard The battery voltage is above
acceptable limits
The machine is disabled check batteries / wiring