- 44 - FC-RIDERS-V2-OP-EN v22.235
Error Internal Label Code Type Description Action Remedy
Brake fault BRAKE_FAULT
26
hard An illegal voltage has been read
from the brake feedback circuit
The machine is disabled
Alarm fault ALARM_FAULT
27
soft
Auxilliary output 1 fault AUX_1_FAULT
28
soft
Auxilliary output 2 fault AUX_2_FAULT
29
soft
Auxilliary output 3 fault AUX_3_FAULT
68
soft
Deck actuator idle
current over limit
BRU_DECK_NULL_ERROR
30
soft An abnormally high idle current
has been detected in the deck
actuator motor
Brush, deck actuator and
water/suds are disabled
Transport motor stalled TRACTION_STALLED_MOTOR
31
hard An energized transport motor is
not rotating
Transport motor circuit
current over limit
LEFT_DRAIN_OV
32
hard There is excessive current in the
transport motor drive circuit
Transport motor circuit
current over limit
RIGHT_DRAIN_OV 33 hard There is excessive current in the
transport motor drive circuit
The machine is disabled
Brush motor current over
software limit
BRUSH_SOFTWARE_OV 34 soft The brush motor current has
exceed the software limit
Brush, deck actuator and
water/suds are disabled
Brush motor current over
hardware limit
BRUSH_HARDWARE_OV 35 soft The brush motor current has ex-
ceed the absolute hardware limit
Brush, deck actuator and
water/suds are disabled
Open circuit detected in
brush motor
BRUSH_OPEN_CIRCUIT 36 soft An electrically open condition
has been detected in the brush
motor circuit
Brush, deck actuator and
water/suds are disabled
REGEN_CURRENT_EXCEEDED 37
LEFT_DRAIN_FAULT 38
RIGHT_DRAIN_FAULT 39
Transport motor current
over hardware limit
LEFT_SOFTWARE_OV 40 hard The transport motor current has
exceed the absolute hardware
limit
The machine is disabled
Transport motor current
over hardware limit
RIGHT_SOFTWARE_OV 41 hard The transport motor current has
exceed the absolute hardware
limit
The machine is disabled
BRUSH_DRAIN_FAULT 42
12VDC power supply
outside acceptable limits
SUPPLY_OUT_OF_RANGE 43 hard The 12VDC supply voltage is less
tha 11.75V or greater than 12.25
volts
The machine is disabled check batteries
VALVE_OPEN_CIRCUIT 44
Deck actuator motor cur-
rent over software limit
BRU_DECK_SOFTWARE_OV 45 soft The deck actuator current has
exceed the software limit
Brush, deck actuator and
water/suds are disabled
Vacuum motor current
over hardware limit
VACUUM_HARDWARE_OV 46 soft The vacuum motor current has
exceed the software limit
The vacuum motor is
disabled
Deck actuator motor
current over hardware
limit
BRU_DECK_HARDWARE_OV 47 soft The deck actuator current has
exceed the absolute hardware
limit
Brush, deck actuator and
water/suds are disabled
Squeegee motor current
over software limit
SQUEE_SOFTWARE_OV 48 soft The squeegee motor current has
exceed the software limit
The squeegee actuator is
disabled