SERVICE MANUAL
ADVANCE OVENS
04/02/2020 102
16.13. AUXILIARY FUNCTIONS (from 01/01/2016)
The Auxiliary Function of the oven is selected by pressing the Auxiliary Function Selector. All the Auxiliary Options
light up and the General Selector is turned until obtaining the required option. Confirm this value by pressing the
Time Selector again or by pressing the General Option Knob.
14 - Auxiliary Options Selector button
15.1 - Cool down display
15.2 - Humidifier display
15.3 - Descaling display
15.4 - Wash display
16.14. COOL DOWN
To cool the cooking chamber, proceed as follows:
With the door closed and the oven temperature higher than 45 ºC, press the Auxiliary Function Selector. Use the
General Options Selector to select the option COOL DOWN. Confirm the option by pressing the Auxiliary Options
Selector or the General Options Selector.
Next open the door.
The fan starts. When the chamber temperature reaches 45ºC, the fan stops automatically.
The cooling cycle can be stopped by pressing the START STOP button again OR by closing the door, and the Cool
Down indicator will go out.
Warning: Do not cool the oven by directly applying cold water in the tub.
SAFETY MEASURES: The fan cover and the tray guides must be correctly fastened in place during this
cycle.
16.15. HUMIDIFIER
To activate the humidifier, press the Auxiliary Options Selector. All the Auxiliary Options light up. Use the General
Selector to select the option Humidify Button. Confirm the option by pressing the Auxiliary Options Selector or the
General Options Selector.
The moisture inlet only operates when the door is closed and the oven is in START mode (in STOP mode the signal
is ignored).
Bakery products rise very well using this function thanks to the rapid entrance of moisture. It also gives baked
products a gentle shine.
It should be used for short periods of time.
16.16. DESCALING
When the oven automatically detects excess lime scale in the pipes, a message is sent via the display General
Information Text informing of the need to descale.
The text DESCALING flashes on the display. The speed of the flash increases with the need for decaling, and when
descaling is obligatory the message is permanently lit (at this point the oven only operates in
convection mode).
The descaling function is performed by the SAT. Therefore if the oven requires descaling please
contact the maintenance technician.
To descale, enter the function by pressing the Auxiliary Function Selector and select the option
DESCALE. Confirm the option by pressing the Auxiliary Function Selector or the General Selector.
16.16.1. LIME SCALE SATURATION DETECTOR
In any operating mode, if the TG probe reaches:
o 125 ºC
The message DESCALE is displayed in the upper text of the screen, and flashes every two seconds.
o 140 ºC
The message DESCALE is displayed in the upper text of the screen, and flashes every one second.
o 155 ºC
The message DESCALE is displayed in the upper text of the screen, and flashes every ½ second.
o 180 ºC
The message DESCALE is displayed continuously in the upper text of the screen, and the oven only
operates in Convection mode.