19.1.1. FREQUENCY VARIATOR PARAMETERS
Parameter Definition
Value
061
Elec
061
Gas
101
Elec+Gas
102
Elec+Gas
201
Elec+Gas
202
P0010
Start
programming
1 1 1 1 1 1
P0100
Value in kW 50
Hz
0 0 0 0 0 0
P0304
Vn (V)
230
230
230
230
230
230
P0305
IN (A)
1.8
1.8
1.8
1.8
1.8
1.8
P0307
PN (kW)
0.37
0.37
0.37
0.37
0.37
0.37
P0310
Fn (Hz)
50
50
50
50
50
50
P0311
rpm (Nom)
1400
1400
1400
1400
1400
1400
P0700
Terminal
2
2
2
2
2
2
P1000
ADC setting
2
2
2
2
2
2
P1080
F. Min. (Hz)
25
25
25
25
25
25
P1082
F. Max. (Hz)
50
50
50
50
50
50
P1120
Time ON (s)
5
5
5
5
5
5
P1121
Time OFF (s)
5
5
5
5
5
5
P3900
End
programming
and recording
data
1 1 1 1 1 1
P0003
Expert level
3
3
3
3
3
3
P0005
Output current
display
27 27 27 27 27 27
P0611
Overload
activation
time
(seconds)
16000 16000 16000 16000 16000 16000
P0640
Current
overload (%)
150 150 150 150 150 150
P1210
Automatic
restart
6 6 6 6 6 6
P1300
Lineal mode
(V/f)
2 2 2 2 2 2
P1800
Base f. Khz
16
16
16
16
16
16
P2000
Setting
reference f. Hz
47 55 55 55 55 55

Table of Contents

Other manuals for Fagor AE-061

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fagor AE-061 and is the answer not in the manual?

Fagor AE-061 Specifications

General IconGeneral
BrandFagor
ModelAE-061
CategoryOven
LanguageEnglish

Related product manuals