N
EW
F
EATURES
(S
OFT
M: 7.
XX
)
Page 1 of 50
CNC 8055 / CNC 8055i
Detected errors
V
ERSION
7.01
1 Detected errors
NBTOOL Variable
The installation and programming manuals indicate that this variable
is read-only from the CNC, PLC and DNC.
Actually, it is read-only from the CNC and DNC and it can only be
used inside a tool-change subroutine.
OPMODE Variable
This variable also returns the following code:
Probe canned cycle for surface measurement (PROBE 3)
The moving direction with K1 is as shown in this figure.
Connection of the KS50/55 adapter:
The installation manual describes how to use this adapter, but the
correct connection is the following:
25 Rapid simulation with S=0
56 User parameter table
57 OEM parameter table
117 Oscilloscope.