EasyManua.ls Logo

Fagor CNC 8065 - Operations with the Axes

Fagor CNC 8065
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
·120·
Remote modules
CNC 8060
CNC 8065
7.
(REF: 1402)
REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
The optical power value depends on the total length of the cable being used. Assigning other
optical power values, e.g. a value of 6 for a length of 3 m, can cause communication errors
due to fiber optic signal distortion.
Display ·D40·. Status and error display.
7-segment display for module status and error codes.
Connectors ·E21A· ·E21B· ·E21C· ·E21D·. Feedback inputs (1 per connector).
4 15-pin female SUB-D HD type connectors. The feedback signals may be incremental (TTL,
differential TTL, Vpp) or communication protocols (SSI).
If the input is configured as TTL, differential TTL or Vpp, it will provide over-current
feedback alarm (300 mA).
If the input is configured as differential TTL, it will provide cable-breakage detection
alarm.
Feedback signals (TTL, differential TTL, Vpp).
Pin. Signal. Function.
1 A Feedback signals.
2/A
3B
4/B
5 I0 Reference signals.
6/I0
7 AL Feedback alarm.
8/AL
9 +5 V DC Voltage supply for the feedback system.
10 +5 V DC
11 GND 0 V reference signal.
12 GND
13 - - - - - -
14 - - - - - -
15 Chassis Shield.
11
15
6
10
1
5
Communication protocols (SSI).
Pin. Signal. Function.
1- - - - - -
2- - - - - -
3- - - - - -
4- - - - - -
5 DATA Data line.
6/DATA
7 CLOCK Clock line.
8/CLOCK
9 +5 V Voltage supply for the feedback system.
10 +5_SENSE
11 GND Reference signal.
12 GND_SENSE
13 - - - - - -
14 - - - - - -
15 - - - - - -
11
15
6
10
1
5

Table of Contents

Other manuals for Fagor CNC 8065