·120·
Remote modules
CNC 8060
CNC 8065
7.
(REF: 1402)
REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
The optical power value depends on the total length of the cable being used. Assigning other
optical power values, e.g. a value of 6 for a length of 3 m, can cause communication errors
due to fiber optic signal distortion.
Display ·D40·. Status and error display.
7-segment display for module status and error codes.
Connectors ·E21A· ·E21B· ·E21C· ·E21D·. Feedback inputs (1 per connector).
4 15-pin female SUB-D HD type connectors. The feedback signals may be incremental (TTL,
differential TTL, Vpp) or communication protocols (SSI).
• If the input is configured as TTL, differential TTL or Vpp, it will provide over-current
feedback alarm (300 mA).
• If the input is configured as differential TTL, it will provide cable-breakage detection
alarm.
• Feedback signals (TTL, differential TTL, Vpp).
Pin. Signal. Function.
1 A Feedback signals.
2/A
3B
4/B
5 I0 Reference signals.
6/I0
7 AL Feedback alarm.
8/AL
9 +5 V DC Voltage supply for the feedback system.
10 +5 V DC
11 GND 0 V reference signal.
12 GND
13 - - - - - -
14 - - - - - -
15 Chassis Shield.
• Communication protocols (SSI).
Pin. Signal. Function.
1- - - - - -
2- - - - - -
3- - - - - -
4- - - - - -
5 DATA Data line.
6/DATA
7 CLOCK Clock line.
8/CLOCK
9 +5 V Voltage supply for the feedback system.
10 +5_SENSE
11 GND Reference signal.
12 GND_SENSE
13 - - - - - -
14 - - - - - -
15 - - - - - -