Remote modules
CNC 8060
CNC 8065
7.
(REF: 1402)
REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
7.7 Software installation/update.
Requirements.
The software of the remote module "RCS-S" (Sercos counter) can only be installed/updated
using Fagor's PC application "WinDDSSetup" with version 08.06 or later.
Therefore, to do that, WinDDSSetup must be previously installed at the PC and the remote
module RCS-S must be connected to the PC through an RS-232 serial line cable.
Process.
• If the "Online" option is shown, uncheck it to enable the "Boot" option. Its associated icon
will also be enabled on the tool bar.
BOOT.
Proceed as follows:
• Run the WinDDSSetup application at the PC.
• Select the label "Work mode" and check the "Boot"option of the pop-up menu.
Click on the "Boot" icon of the tool bar to display the "BootType" window.
Select "BOOT_RCS_S" from the list and click on "validate". That will display the "BootStrap"
window.