·38·
Remote modules
CNC 8060
CNC 8065
3.
(REF: 1402)
RIO70 REMOTE MODULES. (CANFAGOR PROTOCOL).
3.6.1 Elements (connectors).
Connector ·X1·.
Not being used from software version V01.10 on. Previous versions allowed connecting 2
probes of 5 V DC or 24 V DC.
Connectors ·X2· & ·X3· & ·X4· & ·X5·. Feedback inputs (differential TTL and sinusoidal
1 Vpp).
4 15-pin female SUB-D HD type connectors.
To connect feedback devices with differential TTL or 1 Vpp sinusoidal signals. See
"3.8 Feedback inputs. Technical characteristics and connection." on page 40.
(*) Pin ·15· is offered for compatibility. We recommed to connect the cable
shield to the connector housing at both ends.
Pin. Signal. Function.
1 A Feedback signals.
2/ A
3B
4/ B
5 I0 Reference signals.
6 / I0
7 AL Feedback alarm.
8/ AL
9 +5 Vdc Voltage supply for the feedback system.
10 - - -
11 GND 0 V reference signal.
12 - - -
13 - - -
14 - - -
15 Chassis(*) Shield.