Remote modules
CNC 8060
CNC 8065
4.
(REF: 1402)
·49·
RIO5 REMOTE MODULES. (CANOPEN PROTOCOL).
4.1 Dimensions and mounting of the modules.
Place the modules on 2 profiles, according to the UNE 50022 standard, with 2 securing ends,
one at each end of the group; they help securing the modules besides maintaining the right
gap between the profiles.
Dimensions of the modules.
Always leave a 140 mm gap under the modules for ventilation and later handling.
Connection of the modules.
The modules of the group are connected as follows:
A For ground connection.
B Ribbon cable to interconnect the modules.
C Securing ends.
Each group is connected to the system (CPU, Keyboard, etc.) through the CAN bus as
described later on.
DO NOT make any connection or connect any module to the power supply while the latter is turned
on. Before making any connection, ribbon cable included, turn the power supply off by unplugging the
power cable.