Remote modules
CNC 8060
CNC 8065
3.
(REF: 1402)
·27·
RIO70 REMOTE MODULES. (CANFAGOR PROTOCOL).
3.1 Dimensions and mounting of the modules.
Place the modules on 2 profiles, according to the UNE 50022 standard, with 2 securing ends,
one at each end of the group; they help securing the modules besides maintaining the right
gap between the profiles. The mounting order to be followed from left to right is:
• Power Supply.
• Counters.
• Analog outputs. Half size.
• Analog inputs. Half size.
• Digital outputs. Half size.
• Digital inputs. Half size.
Dimensions of the modules.
Always leave a 140 mm gap under the modules for ventilation and later handling.
Connection of the modules.
The modules of the group are connected as follows:
A For ground connection.
B Ribbon cable to interconnect the modules.
C Securing ends.