·36·
Remote modules
CNC 8060
CNC 8065
3.
(REF: 1402)
RIO70 REMOTE MODULES. (CANFAGOR PROTOCOL).
3.5.1 Elements (connectors).
Connector ·X1· & ·X2·. Analog inputs (4 inputs in each connector).
10-pin male Phoenix minicombicon contact (3.5 mm pitch).
Each analog input has three pins (I+, I-, SH). Use shielded cables connecting their meshes
to the corresponding shield pin.
Connector ·X1·. Analaog outputs (4 outputs in each connector).
12-pin male Phoenix minicombicon contact (3.5 mm pitch).
Each analog output has three pins (O+, O-, SH). Use shielded cables connecting their
meshes to the corresponding shield pin.
I1+
I1-
SHIELD
I2+
I2-
I3+
I3-
SHIELD
I4-
I4+
I5+
I5-
SHIELD
I6+
I6-
I7+
I7-
SHIELD
I8-
I8+
Signal. Function.
I1+ I1- Analog inputs.
SHIELD Shield connection.
Signal. Function.
O1+ O1- Analog outputs.
O2+ O2- Analog outputs.
O3+ O3- Analog outputs.
O4+ O4- Analog outputs.
SHIELD Shield connection.
O1+
O1-
SHIELD
O2+
O2-
SHIELD
O3+
O3-
SHIELD
O4+