·48·
Hardware configuration
CNC 8065
4.
(REF: 1404)
CENTRAL UNIT ICU.
CAN bus. ·CAN· connector.
5-pin male Phoenix minicombicon contact (3.5 mm pitch).
For further information on how to configure the connection of the elements to the CAN bus,
refer to chapter "10 Bus CAN (CANfagor/CANopen protocols)." of this manual.
CAN bus. ·ST· selector.
Line terminating resistor. The ·LT· switch identifies which are the elements that occupy the
ends of the CAN bus; i.e. the first and last physical element in the connection.
The switch position of the terminating elements must be "1" and that of the rest of the
elements "0".
CAN bus. ·ERROR· LED.
Red LED. Its meaning depends on the blinking speed.
CAN bus. Led ·RUN·.
The LED is green. Its meaning depends on the blinking speed.
Bus used to communicate with Fagor drives. Sercos Bus.
·IN· & ·OUT· connectors Honeywell emitter and receiver.
For further information on how to configure the connection of the elements to the Sercos bus,
refer to chapter "11 Sercos Bus." of this manual.
Type of blinking. Meaning.
LED off. The module works properly.
Blinking fast. Module configuration stage.
Single blinking. Warning. Poor transmission.
Double blinking. There is no communication with the cpu.
LED on. Error. Too many errors.
Type of blinking. Meaning.
LED on. The module works properly.
Single blinking. Module stopped.
Blinking fast. Module configuration stage.
Continuous blinking. Start-up stage or error.
1
2
3
4
5
ISO GND
CAN L
SHIELD
CAN H
SHIELD
Pin. Signal. Function.
1 ISO GND Ground / 0 V.
2 CAN L (LOW) bus signal.
3 SHIELD CAN shield.
4 CAN H (HIGH) bus signal.
5 SHIELD CAN shield.
Signal. Function.
IN Sercos signal receiver.
OUT Sercos signal emitter.