EasyManua.ls Logo

Fagor CNC 8065 - Probe Connection

Fagor CNC 8065
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
·64·
Hardware configuration
CNC 8065
4.
(REF: 1404)
CENTRAL UNIT ICU.
4.10 Probe connection.
The CNC has two probe inputs, 5 V and 24 V. The following diagrams use the first probe input
(pins ·2· to ·5·); to use the second input, use pins ·6· to ·9·.
All the shields of the cables must be connected to ground only a the CNC through pin ·1·
of the connector, leaving the other one free. The unshielded portion of the wires of a shielded
cable cannot be longer than 75 mm.
Probe whose output has a normally open contact. Connection to +5 V.
The connection acts upon the up flank (positive pulse) of the probe signal.
Probe whose output has a normally open contact. Connection to +24 V.
The connection acts upon the up flank (positive pulse) of the probe signal.
Probe whose output has a normally closed contact. Connection to +5 V.
The connection acts upon the up flank (positive pulse) of the probe signal.
Probe whose output has a normally closed contact. Connection to +24 V.
The connection acts upon the up flank (positive pulse) of the probe signal.
PROBE
1
2
5
3
4
Chassis
+ 5 V
GND
PRB1_5
PRB1_24
PROBE
1
2
5
3
4
Chassis
+ 5 V
GND
PRB1_5
PRB1_24
+ 24 V
PROBE
1
2
5
3
4
Chassis
+ 5 V
GND
PRB1_5
PRB1_24
10K
PROBE
1
2
5
3
4
Chassis
+ 5 V
GND
PRB1_5
PRB1_24
50K
+ 24 V