CQR-32/56 Fagor Compact Drives and Motors Quick Reference. Ref.1910
FM7. E03 series. Flange mounting
FM7. HS3 series. Flange mounting
Units in mm
L LA LB LC LG LH LL LR LD LE LF Z D I KD KL KI KE Q QR S
FM7-D055-S1D0-E03 475 215 180h7 204 20 250 415 60 353 226 171 15 204 270 42.5 158 204 114 60 0.5 28h6
FM7-D075-S1D0-E03 506 215 180h7 204 20 250 446 60 401 256 190 15 204 270 42.5 164 250 114 60 0.5 28h6
FM7-D110-S1D0-E03 556 265 230h7 250 25 300 476 80 420 271 205 15 260 343 42.5 183 279 131 80 0.5 38h6
Units in inches
LLALBLCLGLHLLLRLDLELFZ D IKDKLKIKEQ QR S
FM7-D055-S1D0-E03 18.7 8.4 7.1h7 8.0 0.7 9.8 16.3 2.3 13.8 8.8 6.7 0.5 8.0 10.6 1.6 6.2 8.0 4.4 2.36 0.02 1.1h6
FM7-D075-S1D0-E03 19.9 8.4 7.1h7 8.0 0.7 9.8 17.5 2.3 15.7 10.0 7.4 0.5 8.0 10.6 1.6 6.4 9.8 4.4 2.36 0.02 1.1h6
FM7-D110-S1D0-E03 21.9 10.4 9.1h7 9.8 0.9 11.8 18.7 3.1 16.5 10.6 8.0 0.5 10.2 13.5 1.6 7.2 10.9 5.1 3.15 0.02 1.5h6
LB
LG
5
KD
D
KL
KE
4 - Ø Z
L
H
L
A
Diameter of
mounting hole
KI
LC
I
L
LL
LD
LF
LE
Q
LR
Detail of the shaft extension
Symbol indicating the direction
of the cooling air
S
Ø6
Q
R0.5
dx
30°
mxl
X1
X2
X3
X4
RH
Right-hand
screw
Ø18 ± 0.003
Ø45
Ø65
Ø100
Ø120
20
Ø19
xxxxx
xxx
x
x
M16x1.5
LH
A
A
Aprox.2
A
A
7.5
11.5
0.5
24
7.5
30°
Left-hand screw
KI
KL
KE
L
A
L
H
I
LC
4 - Ø Z
Diameter of
mounting hole
LL
LT LL LR
LF LE
LD
LG
5
Q
LB
I1
L1 L2
L3
I2
Detail of the shaft at the end opposite to the load
Detail of the shaft at the load end
indicates the direction of the cooling air
With seal
Direct coupling only
Use the clean air through the air drier and filter for
sealing air
Air pressure: 1 kg/cm²