Fagor Compact Drives and Motors Quick Reference. Ref.1910 CQR-55/56
VECON-X BOARDS
ACD/SCD - ... - L MODELS
Drive software versions older than 09.05 are NOT compatible with
ACD/SCD X.X-...-L models (input line voltage: 3-ph. 200/240 V AC).
TRANSFER OF · *.MOT · FILES · MOTOR TABLE
Transferring any (*.mot) motor file (AKA motor table) whose version
is higher than 02.01 requires having a software version 08.09 or
higher installed at the drive.
SOFTWARE INTERFACE VECON BOARD
Up to 06.01 SERCOS VECON
06.01 up to 06.17 SERCOS VECON-2, VECON-3
06.18 up to 06.25 SERCOS VECON-2, VECON-3
06.26 and later SERCOS VECON-2, VECON-3, VECON-4
07.0x CAN VECON-2, VECON-3
08.01 to 08.04 CAN VECON-2, VECON-3
08.05 to 08.09 SERCOS/CAN
VECON-2, VECON-3,
VECON-4 (vers.00A)
08.10 and later SERCOS/CAN
VECON-2, VECON-3,
VECON-4 (vers.00A and later)
Note. Drive software versions older than 08.09 are NOT compatible
with motor table version 02.02 or higher.
SOFTWARE VERSION MOTOR TABLE VERSION
Up to 08.08 included 02.01
08.09 02.02
08.10 02.03
08.11 02.03
08.12 02.05
08.13 02.06
08.14 02.07
08.16 02.08
08.17 | 08.18 | 08.19 02.09
08.20 02.10
09.01 02.11
09.03 | 09.04 | 09.05 02.12