Drive modules
DRIVE MODULES
Modular drives
3.
139
DDS
HARDWARE
Ref.1310
Connectors at slots SL1 and SL2
CARD A1
The A1 card must always be in slot SL1.
X6-DIGITAL I/Os, digital inputs and outputs
If offers 4 digital inputs and 4 digital outputs, all of them fully programma-
ble.
The digital inputs are optocoupled and referred to a common point (pin 5).
The digital outputs are contact type and also optocoupled.
Each input and output is associated with a parameter. The user may as-
sign to these parameters, internal Boolean type variables that may be
used to show the system status via electrical contacts. See
“man_dds_soft.pdf” manual.
These assigned Boolean variables are set with the monitor program for
PC (WinDDSSetup).
Digital inputs
characteristics
Digital outputs
characteristics
F. H3/76
A1 card: X6-DIGITAL I/Os. Digital inputs and outputs.
IN 4
IN 3
IN 2
OUT 4
OUT 3
OUT 2
OUT 1
REF-IN
IN 1
1
13
7
6
3
5
4
8
2
1
9
11
13
12
10
Pin
Phoenix
3.5 mm
X6-DIGITAL I/Os
A1
1
1
X7-ANALOG I/Os X6-DIGITAL I/Os
P1P2
(A1 Board)
Maximum rated voltage 24 V DC (36 V DC)
ON/OFF voltage 18 V DC (5 V DC)
Maximum typical consumption 5 mA (7 mA)
Maximum voltage 250 V
Maximum load current (peak) 150 mA (500 mA)
Maximum internal resistance 24
Galvanic isolation voltage
3750 V (1 min)