Drive modules
188
3.
DRIVE MODULES
Modular drives
140
DDS
HARDWARE
Ref.1310
X7-ANALOG I/Os, digital inputs and outputs
It offers 2 inputs and 2 outputs, all of them fully programmable. Each in-
put and output is associated with a parameter. See “man_dds_soft.pdf”
manual. It offers a ± 15 V power supply for generating a command easily.
Pinout
Analog input 1
Associated with pins 4 and 5. It is the usual input for the velocity com-
mand (± 10 V DC) generated by the CNC.
Analog input 2 Associated with pins 2 and 3. It is the auxiliary command input.
Analog input
characteristics
F. H3/77
A1 card: X7- ANALOG I/Os. Analog inputs and outputs.
1
11
7
6
3
5
4
8
2
1
9
11
10
Pin
(Phoenix,
3.5 mm)
X7-ANALOG I/Os
A1
1
1
X7-ANALOG I/Os X6-DIGITAL I/Os
P2P1
(A1 Board)
Analog Input 2 (-)
Analog Input 2 (+)
Analog Input 1 (-)
Chassis
Analog Input 1 (+)
OUT1 (+)
OUT1 (-)
OUT2 (+)
OUT2 (-)
+15V DC
-15 V DC
P2
P1
T. H3/13 Description of the pins of connector X7-ANALOG I/O. Analog
inputs and outputs.
1 Chassis
2 Analog input 2 ( - )
3 Analog input 2 ( + )
4 Analog input 1 ( - )
5 Analog input 1 ( + )
6 Adjustment output (-15 V DC) (user)
7 Adjustment output (+15 V DC) (user)
8
Reference for analog output 2 ( - )
Analog output 2 ( + )
9
10
Reference for analog output 1 ( - )
Analog output 1 ( + )
11
Resolution 1.22 mV
Input voltage range ±10 V DC
Input over-voltage
Continuous mode 80 V DC
Transients 250 V DC
Input impedance
With respect to GND 40 k
Between both inputs 80 k
Voltage in common mode 20 V DC