Drive modules
DRIVE MODULES
Compact drives
3.
179
DDS
HARDWARE
Ref.1310
X7 connector
X7. Status of the safety relay
Connector of the compact drive associated with the second contact (N.C.,
Normally Closed) of an internal safety relay (with guided contacts). The
status of the relay (initially closed) may be acknowledged through the two
pins and a CNC, PLC or control panel, i.e. that the relay has actually
opened or closed. These two terminals are identified at the drive as AS1-
AS2. The opening or closing of this relay depends on whether 24 V DC
are present or not at pin 2 “Drive Enable” of control connector X2. For fur-
ther detail on this connector, see
9.2. Interface section of chapter 9.
FUNCTIONAL SAFETY
in this manual.
The following table shows the values for gap, tightening torque, sections
and other data of the aerial plug-in connector for X7:
F. H3/133
Connector X7. External acknowledgment of the status of the safety relay.
T. H3/28 Data of the pins of plug-in connector for X7.
ACD/SCD/CMC SCD
1.08/1.15/1.25/2.35/2.50 2.75
Connector data
Nr of poles 2 2
Gap (mm) 5.00 5.00
Min/max tightening torque (Nm) 0.5/0.6 0.5/0.6
Screw thread M3 M3
Min./max. section (mm²) 0.2/2.5 0.2/2.5
Rated current In (A) 12 12
Wire data
Length to strip (mm) 7 7