Falcon E163i - FAULT FINDING; ERROR CODES

Falcon E163i
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
8.0 ACCESSORIES
9.0 FAULT FINDING
9.1 ERROR CODES
9.1.1 Most faults can be rectified by simply switching unit off for 10 seconds. After this time,
turn power back on at mains supply. If fault continues to occur after such action then
please refer to the table. This will provide a solution to rectify the condition.
ERROR CODE
DESCRIPTION
POSSIBLE CAUSE OF ERROR
REMEDY
Er 20
Flash memory TC error
μC- defective
Replace generator
Er 22
Button evaluation defective, UI
shuts off after 3.5-7.5 sec
Short or open circuit in the
area of the button sensoric
Replace generator
Er 31
Incorrect configuration data or
deviation between generator and
Controls
New configuration of the
induction generator
required
Replace generator
Er 36
NTC value defective on Control; UI
turns off
Short or open circuit of
NTC
Replace generator
Er 47
Communication error between
TC and induction
No or erroneous LIN
communication! (Slave
does not answer to
request of master)
Connection cable not
correctly plugged in or
defective.
U 400
Continuous tone
Power supply on inlet to high
Incorrect connection of the
cook top
The cook top Correct
power supply
connection
E / 2
Excess temperature of the
induction element
Overload of cooktop or
empty boiled cookware
Let system cool down.
E / A
Error on the power board
Component failure
Replace generator
E / 6
Error on power board or supply
element
No power supply of the
power element or error on
power board
1. Check wiring
2. Replace generator
E / 8
Incorrect fan speed
Error on fan left or right
1. Air exhaust blocked,
e.g. by paper
2. Replace Generator
E / 9
Defective temperature sensor on
inductor
Replace generator