Fancom 743 5. Function keys
37
5.21 Situation overview
Prep.feed
FREE Feed can be prepared.
BLOCKED Feed preparation has been blocked manually or
automatically as a result of an alarm.
CONTINUE After manual blocking this setting can be used to continue
the feeding process.
When the alarm has been cancelled, the computer will
automatically continue the feeding process (for example
filling or emptying the weigher or continuing feed transport).
RESET After the alarm has been cancelled the current situation can
be corrected manually. Using a reset the computer will start
again from the beginning of the feeding process. Before
giving a reset, ensure that any filled weighers or augers are
emptied manually.
A= .. ; B= .. --------
A: Feeding process status:
NO
IN
DO
= feeding process is not active
= dosing in is active
= dosing out is active
B: Storage silo number + Blend name.
Weigher cont.
The actual weigher content (accurate to the gram).
Ingredient
The ingredient currently being dosed in or about to be dosed in.
End weight
The weight in the weigher at which the computer stops dosing in the
ingredient named above.
>>Situation overview
Prep.feed FREE
A=NO B= 0
--------
Weigher cont. 0.345
Ingredient --------
End weight 400
Stor.silo dem. FULL
Pphase= 0 Tphase= 0
Hopper EMPTY
Mixer NO