Table for choosing intercoms and accessories for the required type of installation
Number of Exhito Exhito Studio Compact Application dia-
intercommunicating EX320 EX301 EX310 EX301 ST720W ST701 KM810W ST 701 gram on page:
2 2020222 2 176
3 333336 176
4 4 8 4 12 176
5 5 15 5 20 167
6 6 24 6 30 177
7 7 35 7 42 177
8 8 48 *
* upon request
5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 1 EXTERNAL DOOR
STATION WITH SINGLE CALLS
INTERNAL STATIONS
EXHITO series STUDIO series COMPACT series
... EX320 ... EX310 ... ST720W ... KM810W
... EX301 ... EX301 ... ST701 ... ST701
EXTERNAL DOOR STATIONS
PROFILO series MATRIX series MODY series
... PL71÷PL73 ... MA71÷MA73 ... MD71÷MD73
1 PL81÷PL83 1 MAS61÷MAS63 (
1
)1 MD81÷MD83
1 PL91÷PL93* 1 MA91÷MA93* 1 MD91÷MD93*
1 PL10P÷PL12P 1 MAS10P÷MAS12P 1 MD10÷MD124
... PL21÷PL228 ... MAS22-MAS24 ... MD21÷MD228
... PL20-PL50 ... MAS20 ... MD20-MD50
1 MD30
VARIOUS ARTICLES
1 PRS226E Power supply-switcher
1 PA ** Door release push-button (optional)
1 SE ** Electric door lock (12VAC-1A)
Application diagram
When using MD100, MD200, RP200, UP12 and UP200 ampli-
fied external door stations (RP and UP series for two-way
systems only) place this diagram on the diagram on page 167
and line it up with the riser.
Warning.
- In the external door stations RP200
cut the jumper W1.
- In the external door stations UP do
not connect the yellow wire and insu-
late it.
- For alternate current wires refer to
note 6 of the installation instructions
on page 146.
... Refers to number of users (see table on the bottom of this page).
(
1
) Or MA61÷MA63.
* Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Working instructions. See page 183.
Notes
- Do not forget to connect terminals C of the additional buttons.
- For the connection of name-plate lamps, read notes 6 and 7 of the
installation instructions on page 146.
- For wires dimensioning refer to installation instructions and table on page
146.
ST 720
EX320

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FARFISA INTERCOMS ECHOS and is the answer not in the manual?

FARFISA INTERCOMS ECHOS Specifications

General IconGeneral
BrandFARFISA INTERCOMS
ModelECHOS
CategoryIntercom System
LanguageEnglish

Related product manuals