Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
8-1
8 SPECIAL FUNCTIONS MENU
8.1 Enter in the special functions menu
Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear.
CAL Calibration of wheel balancer
CAL tSt Control of the calibration of electronic sensors
CAL rod Calibration of electronic input sensors
SEn Sor Diagnostic of sensors
StA tiS Statistic about the use of machine
USr Set User setup
tEc Set Technical Setup
Ser nuM Serial number
Act Cod Inserting Activation Codes
8.2 Diagnostic program of sensors
Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Select Sen Sor and press <SET>.
rPM Balancing speed
PS1 PS1 voltage
PS2 PS2 voltage
tO Encoder is in the zero position
PoS Angle of position sensor(from 0 to 255)
dIS Value of distance sensor
dIA Value of diameter sensor
OUT Value of width sensor
Cou Safety cover is open or closed
PED Air pedal (only PL version)
AIR Pressure guage (only PL version)
8.3 Statistic program
Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Select Sta tis and press <SET>.
tOt Total number of spin
SUC Percent of runs with a good result
c11 0s Percent of wheels with diameter <11"
from 11 to 17 Percent of wheels with the indicated diameter
]17 0s Percent of wheels with diameter >17"
CAL Number of calibrations
pne Number of PL test (only PL version)
8.4 User Setup
Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Select USa SET and press <SET>.
ScA LE Set 1 or 5 grams step (0.05/0.25 ounces).
Cut oFF Set minimum weight to be displayed.
Uni Out Unit of measure for the width (0=inch, 1=millimeters).
Uni Umb
Unit of measure for the weight (0= grams, 1=once).
Fin AL Display of final (0 = normal, 1 = blink, 2= Go OD).
biP Enable/Disable beep in position.
EME StP Motor brakes in case of emergency stop (On or OFF) (OFF: motor power is cut).
Cou Er OFF = safety cover is not installed;
On = the motor starts only if the safety cover is closed;
Aut = closing of safety cover the motor starts automatically.
rod in Enable/Disable distance input system.
rod out Enable/Disable width input system.
STE P Increase distance/width measure.
PNE U Enable/Disable PL system.
SCR EEN Screen saver selection from 1 to 5 (0 = disable).
VOI CE Enable/Disable voice system.
Snr Sensibility to external vibration.
Tim er Input system speed.
Fas t Enable/Disable fast cycle.
APS Enable/Disable automatic position system.
ADM IN Enable/Disable Admin mode.
OPT Set minimum tire matching level.
rES Et Load Factory Setup.