Fasep 2000 srl Rev. 1.3
Balatron B110, B210: User’s Manual 15 July 2013
3-1
General Safety Requirement
[before using/servicing this unit]
1. Read this instruction manual before operating or servicing the wheel balancer.
2. Make sure electrical power source conforms to requirements shown on nameplate (see also model identification chart for
reference).
3. Make sure the unit has a stable position and it’s bolted to the ground.
[when using the unit]
4. Protect power leading to the unit from damage.
5. When work area is being washed, make sure unit is adequately protected.
6. Remove all stones and mud lodged in tire treads before balancing the wheel.
7. Do not touch spinning wheel.
8. Make sure counterweights are securely attached before checking residual unbalance.
[when servicing the unit]
9. Make sure power sources are disconnected before service on the unit is performed.
10. Service to PCB, electrical and mechanical parts should be done only by an Authorized FASEP 2000 Service Center.
C: Errors and Malfunctions recognized by the Computer
Errors may apply to some model only.
ERR 1 Shaft does not rotate
ERR 16
Calibration memory error
ERR 2 Rotation Direction is wrong ERR 17 Rod in uncorrected position
ERR 3 Rotation speed is not ready ERR 18 Excessive weight detected
ERR 4 Rotation speed is wrong (too low or too high) ERR 19 Reserved
ERR 5 Position Sensor or Position Disk failure ERR 20 Excessive Deceleration
ERR 6 Safety Safety cover is open ERR 21 Error in inputting data
ERR 7 Measuring cycle was interrupted ERR 22 Brake error
ERR 8 Calibration weight was not inserted ERR 23 Reserved
ERR 9 Activation code not correct ERR 24 Insufficient air pressure (PL version)
ERR 10 Overflow in calculations ERR 25 Reserved
ERR 11 Serial number is wrong ERR 26 Piezo sensor error
ERR 12 Serial number not inserted ERR 27 Wheel is not securely tightened on the shaft
ERR 13 Reserved ERR 28 Laser error
ERR 14 Uncorrected password ERR 29 Reserved
ERR 15 E²prom error
For a complete and updated list of error codes on the machine together with resolution procedure, please visit http://support.fasep.it/kb