37X INSTALLATION & OPERATION MANUAL
372/373 MODEL
16
4
Once the barrel has defrosted, navigate to the MANUAL ON/OFF menu located under the SERVICE
MENU section and activate both the CO and solution solenoids for the barrel to be sanitized.
5
Place a large container under the dispensing valve and drain the barrel. Activating the beater
motor will facilitate draining the barrel when near empty. Deactivate the solution solenoid when
the syrup lines have been purged. Continue purging the barrel and then deactivate the CO
solenoid when the barrel has been emptied.
6 Turn o the water supply at the solution module using the shuto valve.
7 Place the syrup BIB connector with adapter in the sanitizing solution.
8
Activate the solution solenoid and begin lling the barrel with sanitizing solution. Pull the relief
valve as necessary to vent the pressure allowing the ll process to continue. Deactivate the
solution solenoid when the barrel is 3/4 full.
9 Activate the beater motor and agitate for three minutes.
10
While the beater motor is agitating, dispense some sanitizing solution from both the relief valve
and the sample valve to ensure they are both sanitized as well.
11 Remove the BIB connector from the sanitizing solution and reconnect to the syrup supply.
12 Activate the solution solenoid.
13
Place a large container under the dispensing valve and drain the barrel. Activating the beater
motor will facilitate draining the barrel. Deactivate the solution solenoid when the syrup lines
have been primed with syrup. Continue purging the barrel and then deactivate the CO solenoid
when the barrel has been emptied.
14 Restore the water supply.
15
Activate the solution solenoid and beater motor again. When the barrel is 1/2 full, deactivate the
solution solenoid to stop the ll process.
16
Activate the CO solenoid and drain the barrel. This step removes the remaining sanitizing solution
left in the barrel. Deactivate the CO solenoid and beater motor when the barrel is empty.
17
Navigate to the MAINTENANCE MENU and start the FILL BARREL process. Follow the prompts until
the barrel is full.