37X INSTALLATION & OPERATION MANUAL
372/373 MODELS
43
Error #150: High Regulated CO PSI
The regulated CO pressure is above 70 PSI (483 kPa).
Error #160: Low Line Voltage
The voltage supply is below 200 volts.
Error #170: High Line Voltage
The voltage supply is above 254 volts.
Error #180: LPSI Transducer
The low side refrigeration pressure is not reading correctly.
Error #200: Return Temperature Sensor
The refrigeration return (suction) temperature sensor is not reading correctly.
Error #270: Air Out
The compressed air pressure is less than 45 PSI (310 kPa).
1 Ensure the pressure transducer is plugged in.
2 Replace the transducer if faulty.
1
Install a boost transformer or Automatic Voltage Regulator (AVR). Even if the voltage is slightly
above 200V, a boost transformer or AVR may be needed as uctuations in power during the day,
or during dispenser operation may cause it to drop below 200 volts and shut down the dispenser.
Note: For optimal performance and to avoid component failures, FBD recommends dispenser be
supplied with 230 VAC ± 10%.
1
Install a buck transformer or Automatic Voltage Regulator (AVR).
Note: For optimal performance and to avoid component failures, FBD recommends dispenser be
supplied with 230 VAC ± 10%.
1 Check the “carbonation” regulator on the header tray and ensure it is set to 60 PSI (414 kPa).
1 Verify there is a supply of compressed air.
2 Ensure the compressed air shuto valve at the back of the dispenser is not turned o.
3 Ensure the gas pressure transducer is connected and working properly.
4
Ensure the compressed air supply pressure at the dispenser is reading 70 PSI (483 kPa). Adjust the
regulator if needed.
1 Ensure the temperature sensor is plugged in.
2 Replace the sensor if faulty.