37X INSTALLATION & OPERATION MANUAL
372/373 MODELS
44
Error #280: N Out
The N pressure is less than 45 PSI (310 kPa).
Error #290: Gas #1 - CO Out
The CO pressure is less than 45 PSI (310 kPa) for barrels 1 and 2 (standard 372 multi-gas) and barrel 1 (372 multi-flavor,
universal gas).
Error #352: Flavor Out 1
Error #362: Flavor Out 2
Error #372: Flavor Out 3
Error #382: Flavor Out 4
The pressure for flavor syrup is less than 45 PSI (310 kPa), where the “Out” number represent the flavor number.
1 Replace or rell the CO tank.
2 Ensure the CO shuto valve at the back of the dispenser is not turned o.
3 Ensure the CO pressure transducer is connected and working properly.
4
Ensure the CO supply pressure at the dispenser is reading 70 PSI (483 kPa). Adjust the regulator if
needed.
1 Replace or rell the N tank.
2 Ensure the N shuto valve at the back of the dispenser is not turned o.
3 Ensure the N pressure transducer is connected and working properly.
4
Ensure the N supply pressure at the dispenser is reading 70 PSI (483 kPa). Adjust the regulator if
needed.
1 Replace the empty BIB.
2 Ensure the gas line is connected to the BIB pump.
3 Ensure the BIB pump is operating correctly.
4 Ensure the gas tank is not empty.
5 Ensure any syrup shuto valves at the back of the dispenser are not turned o.
6
Ensure the syrup supply pressure at the dispenser is reading 70 PSI (483 kPa). Adjust the regulator
if needed.
7 Ensure the syrup pressure transducer for that avor is connected and working properly.

Table of Contents