7.3 MACHINE SETTINGS
These settings are preset by the machine. DO NOT change unless there is a problem with
drink quality.
Mode
L Side Settings Level Control = 3 The higher the value, the higher the product level
Center Settings in the chamber.
R Side Settings The lower the value, the lower the product level in
the chamber.
The lower the value, the harder and colder.
Thaw/Freeze = 3 The higher the value, the higher the drink
temperature.
The lower the value, the lower the drink
temperature.
For more frozen, use lower values.
For more liquid or less frozen, use higher values.
Test for proper drink temperature (24°F to 28°F)
before adjusting.
Defrost Max Time Max Def Time = 420 Number of minutes “Defrost Cycle” will run unless
“Return Temperature” reaches 50°F first.
Common Settings Voltage Offset = 0 Use this offset to match the “Line Voltage” readout
(in “Common Readouts”) to the actual incoming
voltage measured with a voltmeter at L1 and L2 of
the contactor.
This must be completed prior to starting machine for operation.
1. Measure, with a voltmeter, incoming line voltage at L1 and L2 of contactor and record.
2. Read LCD “Line Voltage” reading under READOUTS - Common Readouts and compare
with voltmeter reading. [If within two (2) volts, skip Steps 3 and 4.]
3. Using Voltage Offset, enter valve that will allow LCD Line Voltage readout to match the
voltmeter reading.
4. Once this is set, the machine is ready to run.