14
FBD
FWDBACK SELECTCANCEL
OFF
RIGHT SIDE
FILL BEATER
RUN
DEF.
LEFT SIDE
FILL BEATER
RUN
OFFDEF.
CENTER
FILL BEATER
RUN
OFFDEF.
CRITICAL REGULATOR AND FLOW CONTROL SETTINGS
SET ALL PRESSURES USING THE LCD READOUTS ON THE UNIT - NOT BY THE GAUGES ON THE
REGULATORS!
CO
2 PRIMARY REGULATOR The CO2 Primary Regulator MUST BE SET TO 70-72 psig
(482.6 TO 496.4 kPag).
CO2 SECONDARY REGULATOR The CO2 Secondary Regulator SHOULD BE SET AT 28-32 psig
(Secondary Regulator) (193.1 TO 220.6 kPag) STATIC PRESSURE.
For low carbonation applications, see Quick Reference Sheet on
page 4 for settings information. The CO2 Secondary Regulator is
on the header assembly which is behind the access panel. This
regulator is a “non-vent” regulator. This means that if you lower
the regulator setting, you will need to dispense drinks (with “Fill”
activated) until cylinder begins to refill before the new setting will
register on the gauge.
FLOW CONTROLLERS WATER FLOW MUST BE SET TO PROVIDE A FLOW OF
15 OUNCES IN 10 SECONDS BEFORE ADJUSTING THE BRIX.
BRIX MUST BE SET BETWEEN 13.5 - 15. Flow controllers are on
the header assembly. A sample may be taken by fully opening the
sample valve, by turning it clockwise until it stops.
FBD563 Contols
Figure 7.1b
FBD
FWDBACK SELECTCANCEL
OFF
RIGHT SIDE
FILL BEATER
RUN
DEF.
LEFT SIDE
FILL BEATER
RUN
OFFDEF.
FBD562 Contols
Figure 7.1a