TROUBLE CAUSE REMEDY
(Item 13.26 continued from previous page.)
F. Solution Solenoid F. Activate “Solution Sol” in Manual
malfunctioning and not On/Off. Check for 24VAC at coil.
allowing the chamber to fill. Clean solenoid or replace, if
necessary.
G. Relay board not sending G. Test relay board for 24VAC output
power to solution solenoid and 5VDC input on solenoid relay.
coil. Replace Relay Board, if necessary.
13.27 Drinks “collapse” A. Chamber not filled properly. A. Defrost and assure chamber is
or “fall”. (CO
2 is 90% full. Then press “Run”.
escaping from B. CO2 level in drink too high. B. 1. To affect ALL chambers,
the drink.) lower “Reg.CO2” within
28-32 psig range.
2. To affect ONE chamber, raise
the level control settings (using
the instructions in Section 10.2
of this manual).
C. “THAW/FREEZE” settings C. Raise the “THAW/FREEZE” using
are set too low. the instructions in Section 11.2.
D. Air not cleared from chamber D. Follow “Filling the chamber”
prior to filling chamber. instructions in Section 6.3.
E. Contaminated Syrup supply. E. Syrup being used is more than
three (3) months old, or is not an
FCB syrup.
F. Contaminants in product from F. Flush chamber and remove excess
excessive lubrication of valve lubrication contaminants.
or seal.
G. Contaminated CO2 or water G. Contact CO2 supplier or plumber.
supply.
13.28 Drink tends to “grow” A. “THAW/FREEZE” settings are A. Lower the “THAW/FREEZE”
or continue to expand set too high. settings using the instructions in
in volume after drawn Section 11.2, this manual.
into cup. B. Incorrect Brix or water/syrup B. Check water and syrup flows and
flow rates. adjust if necessary. Then check
brix (see Section 6.2).
C. CO2 level in drink too high. C. 1. To affect ALL chambers,
lower “Reg.CO2” within
28-32 psig range.
2. To affect ONE chamber, raise
the level control settings using
the instructions in Section 10.2
of this manual.
LCD DISPLAY ERROR MESSAGES
13.29 PresMx, A. Chamber pressure above A. Dispense one (1) drink; see if
Pressure Maximum 55 psig. PMAX recurs.
B. Expansion tank pressure B. Replace expansion tank active
system not working properly. charge regulator.
NOTE:
This is not the same regulator as
used on the header.
C. Tank transducer shorted C. Replace transducer.
at 99 psig.
D. Level Control set too high. D. Level Control settings may need to
be lowered. Set the Level Control
using the instructions in
Section 10.2 of this manual.
(Item 13.29 continued on next page.)
35
NOTE:
For low carbonation applica-
tions, see Quick Reference
Sheet on page 4 for settings
information.
NOTE:
For low carbonation applica-
tions, see Quick Reference
Sheet on page 4 for settings
information.