LCD DISPLAY MESSAGES
(# stands for the barrel number which is L, C, R, or 1, 2, 3, 4)
FBD56X SERIES FROZEN BEVERAGE DISPENSERS
MESSAGE DESCRIPTION
Sleep Unit in “Sleep” mode. Unit is shut down.
CmpSDl This delay is before compressor starts. The time period varies from 1 to 20 seconds.
CmpStr This is displayed when compressor starts freezing or defrosting.
CmpRun This is displayed only on Left Side, when compressor is running.
DEF-WT This side is waiting to defrost.
DEFBtr If “DEF” is pressed and if the beater has not been running, then this is displayed.
DEFCWt Time delay while the compressor is starting.
Defrst This is displayed when side is DEFROSTING.
DEFSpd This is displayed when a side has been interrupted by the other side freezing. After the other side
has frozen down, then defrost is resumed.
RunOff This is displayed when freeze is off or when the side is turned off.
RunHGW This is displayed on the opposite side when a side has defrosted and is waiting to refreeze or when
one side is defrosting and the other side is in Run Thaw Mode.
RunCWt This is displayed, prior to starting a freeze down; this is a time delay when the compressor is
starting.
RunFW This is displayed after the freeze down has finished.
RunFrz This is displayed when a side is freezing down.
RunThW This is displayed after the Thaw percent has been reached.
RunTha This is displayed when a side is Thawing before refreezing.
RunB If “Run” is pressed and if the beater has not been running then this is displayed for a maximum time
delay of two (2) minutes.
FilOff The unit will not fill with product when this is displayed.
LFillH This is displayed during first freeze. The pressure in the chamber has not dropped below the fill
pressure.
Fill H This is displayed during normal operations when the pressure in the chamber has not dropped
below the fill pressure.
LfPCO2 This is displayed prior to filling the chamber with solution. This only allows CO
2 into the chamber
for a specified time period.
LfCO2S This is displayed prior to filling the chamber with solution. This only allows CO
2 and solution to fill
the chamber until four (4) psig is reached in the chamber.
LFill This is displayed during first freeze. The unit is filling the chamber.
Fillng This is displayed during normal operations when the chamber is filling.