BLUEHELIX TECH RRT 24 C
18 EN
cod. 3541P250 - Rev. 01 - 07/2018
Position of terminals
fig. 28
Minimum dimensions of fume exhaust terminals
A Directly under an opening, air inlet, openable window, etc. 300 mm
B Above an opening, air inlet, openable window, etc. 300 mm
C Horizontally to an opening, air inlet, openable window, etc. 300 mm
D Under gutters, drain pipes 75 mm
E Under cornices or under eaves 200 mm
F Under balconies or garages 200 mm
G From a drain pipe or a vertical drain pipe 150 mm
H From an internal or external corner 100 mm
I Above ground level, a roof or balcony 300 mm
J From a surface facing the terminal 600 mm
K From a terminal facing the terminal 1200 mm
L From a garage opening (e.g. door, window) with access to the home 1200 mm
M Vertically from a terminal on the same wall 1500 mm
N Horizontally from a terminal on the same wall 300 mm
O From the wall on which the terminal is fitted N/A
P From a vertical structure on the roof 150 mm
Q Above the intersection with the roof 300 mm
NOTES
N/A = Not applicable
Also, the terminal must be at least 150 mm (fanned draught) from an opening made in the structure of the building to
house a fitted element such as a window frame.
Positions of flue terminals: if the flue is installed at a low level the potential effect of the plume must be considered.
Special plume management kits are available by request.
The plume must not be directed towards:
- A frequented approach
- A window or door
- An adjacent property
P
D, E
Q
Q
l
B
C
A
G
F
L
J
H
H
K
N
N
MM
Q