EasyManuals Logo

Festo CMMP Series Brief Overview

Festo CMMP Series
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Festo P.BE-K-CMMP-AS-C20 1010NH English 25
Main
index
Sub-
index
Error message
Cause/measure
15
x
Division by zero
Please contact Technical
Support.
16
x
Initialiszation fault
17
x
Drag error
Enlarge fault window,
reduce acceleration
21
x
Fault in offset current
measurement
Please contact Technical
Support.
22
x
Fault in PROFIBUS
Slave address, bus
termination and cabling
Please contact Technical
Support.
25
x
Invalid device type
Please contact Technical
Support.
26
x
Checksum fault
27
x
Warning threshold
drag error
Check parametrizing
28
x
Operating time
counter
Acknowledge fault. If fault
occurs again, contact
technical support.
30
x
Internal conversion
fault
Please contact Technical
Support.
31
x
I
2
t-fault
Mechanic part blocked,
check application.
32
x
Intermediate curcuit
Please contact Technical
Support.
33
x
Drag error in encoder
emulation
34
x
Synchronization fault
in field bus
No synchronization
messages from the master.
35
x
Protection against
slipping of linear
motor
Sensor signals are faulty.
Check the installation.
36
x
Parameter fault
Check user parameter
record.

Other manuals for Festo CMMP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CMMP Series and is the answer not in the manual?

Festo CMMP Series Specifications

General IconGeneral
Control ModePosition, Torque
Communication InterfacesCANopen, EtherCAT, PROFINET, Ethernet/IP
Power Supply24 V DC
Feedback SystemIncremental encoder, Absolute encoder
Number of axes1
Relative humidity5% to 95% (non-condensing)
Operating temperature0 °C ... +50 °C