Festo SPC11 2018-12b English 7
Specially for measuring systems type MLO-POT-...-TLF:
S Mount the measuring system so that it is electrically
isolated.
S If the measuring system is to be used in a dusty or
dirty environment, mount it so that the actuator slide
faces downwards.
Specially for measuring systems type MLO-POT-...-LWG:
S In order to earth the system, connect the earth/ground
cable on the flat plug of the measuring system to the
earth connection on the SPC11.
Specially for DNCI-...
S In order to earth the earth connection of the SPC11
and the earth connection of the drive, connect them
with the same earth potential.
Fixed stops
S Use fixed stops to limit the working stroke. With drives
of type DGP(I)(L)-..., the working stroke should not
project into the range of the end position cushioning.
Mass load
S Fasten the permitted mass load to the slide without
play.