Go to fetco.com for the latest versions of all information Page 11 User Guide & Operator instructions P211e0November 2021
DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED
Contact factory or specialized personnel for error codes
001
Software error-error on start up or
corrupted software
Improper start-up or shutdown Restart , if still fault: reload software
002
Internal flash corrupted
internal data memory malfunction
Error found in cyclic
redundancy check CRC
Restart , if still fault: reload software
If not corrected :replace board
Short-circuit in temperature probe
051 Open temperature probe.
Bad probe connection, or probe
failure.
Check all connections. Replace probe if
necessary.
100
Initial fill time took longer than
expected after powering up.
Water supply flow rate is too
low.
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter...)
101
Tank did not refill within expected
Water supply flow rate is too
low.
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter…)
200 Heating flatline-Tank is boiling
Heater is on, temperature is not
rising/dropping
High elevation correction. Bad heaters
or temperature probe or position
201
thermostat, or Solid State Relay
Failure of heating element,
SSR, high limit or low voltage
Check and replace heating elements,
SSRs, high limit devices if necessary.
202 Heater Shorted or Stuck SSR
Heater is off and heating
SSR is stuck “ON”
Check that ohms range of heater are
between 10-80Ω; replace if not. SSR
may be stuck in ON mode-replace SSR.
255 Keyboard [HID] error
Usually from longer than 10 sec
contact. Or faulty reassembly
Restart , if still fault: reload software. If
mechanical: replace module
NO
BSKT
Insert Brew Basket
Brew basket must be in place
This is a
SAFETY FEATURE
Insert brew basket into brewer rails to
enable brewer