Brewer Operation Control Settings, Adjust Brew Flow Rate
POSITION Program Items Factory set Default Programming Range Increments Notes
B1 Tank Temp.
NOTE: Equipment is
77° to 97°C
170°F to 207°F
0.5°C
1.0°F
Chart to correct for
high altitude below
B4
YES YES/NO
To display HW tank
temperature on screen
B5
Units of Measure
TEMPERATURE
° Fahrenheit Fahrenheit/Celsius C/F
NOTE: Overwrites
user settings (see page 9)
B6
Liters Gallons/Liters/Ounces L/Gal/Oz
NOTE: Overwrites
user settings (see page 9)
B7 Customer Name Off NO or YES For name on screen
B7 Customer Name (only if above is “ON) Scroll with batch keys A-Z;a-z;0-9 16 characters total
B9 Demo Mode DEMO ON/OFF
Demonstrates the controls
for training. Disables all
B10 Eco Mode On ON/OFF YES/NO
water tank temperature after
preset time of inactivity
B11 Eco Idle Time 1Hr 1-6 hours 1 hour
Time of inactivity to go into
ECO Mode
B12 Eco Idle Temp 170°F 158-176°F 1 degree
Temperature that hot water
tank is lowered to when in
B13 Filter Life OFF ON/OFF YES/NO
Water filter life is accessed
in G-Counters. This is user
set and will display indicator
Chart to correct for altitude for boiling point
in tank water temperature.
[ft] [m]
Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C]
Boiling
point [°C]
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: “ON”
(FACTORY DEFAULT FOR BREWER)
“BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show “HEATING”
and hot water tank temperature
The “BREW START” entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Controls allow both sides of dual brewer to
operate if one side has an ongoing brew
started and the second side brew is selected.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-
allow brew at low temperature.
Coffee flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-will
allow brew at low temperature.
Coffee flavor will be noticeably affected
Hot water tank not
at brew temp
setpoint.
Tank temp
STOP is not lit
BREW START
buttons not lit.
and are disabled.
When hot water
tank temperature is
will illuminate and
“READY” will be
displayed
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at cold temperature
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The red colored ready lights switch turn off