19
SETTINGS
Press the “Menu” button and then use the “Left or Right” buttons to scroll through the settings
menus. Press the “OK” button to select the setting:
OPERATING MODE SETTING
There are 3 Modes of Operation. In all three modes, the user always controls the “Airflow %” setting by
simply pushing the “UP or Down” buttons at any time. To select the mode, press the “Up or Down”
arrows to scroll the options below and press the “OK” button to confirm your selection.
1. Manual Mode (On/Off)
This mode allows the user to manually choose the on/off state of the blowers in the
Filtrabox. This is the default mode. Toggle “ON/OFF” by pressing the “Power” arrow
key. The blower(s) will be engaged to the previously set “Airflow %”
2. Link On/Off
This mode uses the DB9 connection at the rear or the Filtrabox. The blowers will be
engaged at the previously set “Airflow %” when Laser requests it. (If feature is available
on the Laser.) When the Laser does not require any airflow, the system automatically
deactivates the blowers. If there is no laser system connected, the blowers will never
engage. See the Controller Set-up and Pin-Out example at the end of the manual.
3. Link On/Idle
This mode uses the DB9 connection at the rear or the Filtrabox. The blowers will be
engaged at the previously set “Airflow %” when Laser requests it. (If feature is available
on the Laser.) When the Laser system does not require operating airflow, the system
continues idle at a very low setting to contain fumes from the off-gassing of lasered
materials, and off-gassing of dust in the Filtrabox or the Laser enclosure. See the
Controller Set-up and Pin-Out example at the end of the manual.