EasyManua.ls Logo

FineTek EPD30 - Technical Performance; Execution Standards; Basic Parameters and Performance Indicators

FineTek EPD30
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
9. Technical Performance
9.1 Execution Standards
IEC 60068-2-3 EN 61326-1:2013
IEC 61326-1 EN 55011:2009/A/:2010
IEC 60092-504 ISO 4064-1
JIS B2220 JIS B7554-1997
ANSI B16.5 DIN 25 Series
9.2 Basic Parameters and Performance Indicators
9.2.1 Technical Specification Table
Item
EPD30
Display
LCM 128* 64 pixel backlit type
Buttons
Tri-button operation
Communication interface
RS-485 (Modbus) (Optional support for ZigBee Pro wireless transmission)
Accuracy
±0.5% of reading@1m/s(0.2% optional)
Medium temperature
-20~120℃
Ambien temperature
-40~70℃
1
Fluidic conductivity
>5uS/cm
Measuring scope
0.1m/s~10m/s
Current output accuracy
0.1% of Pulse Output Accuracy
Temperature coefficient (100ppm/℃)
Operating pressure
10 kg/cm
3
Current output mode
Proactive
Analog output
4~20mA
Maximum load of current output
<700Ω
Alarming current
3.6mA or 22mA
Frequency output scope
2~8KHz
Pulse width
Automatic (pulse width 50%)
Pulse mode
NPN transistor output 32vdc/200mA
Time constant
1~100s
Control output (DO)
NPN transistor output 32vdc/200mA;1-CH
Control input (DI)
Dry contact ON< 200Ω ;
1,000Ω< OFF ; 1-CH
Baud rate
1200~57600 bps
Protection rating
IP67/NEMA 4X
Enclosure material
Aluminum alloy
Input power
AC100~240V or DC24V
Power consumption
<10 W
Wire inlet specification
M20 x1.5*2
Excitation mode
Pulse DC
Vibration regulation
IEC 60068-2-3
EMC regulation
IEC/EN 61326-1 Class A table 2
1
It can’t display when LCM is lower than -20℃.

Table of Contents