OPERATION
Connecting
LPG
Fuel
~
WARNING!
Liquid
Petroleum
gas
(LPG)
is
extremely
flammable
which
could
cause
burns
or
fire
resulting
in
death
or
serious
injury.
The
fuel
supply
line
must
always
be
shut
off
when
the
engine
is
not
running.
Failure
to
shut
off
fuel
may
allow
fuel
to
leak
at
the
generator.
Do
not
place
the
LPG
sources
in
the
path
of
muffler
outlet
or
near
any
ignition
source.
Keep
a
fire
extinguisher
near
the
generator
all
the
time.
Do
not
use
or
store
LPG
portable
sources
not
in
use
near
generator
or
in
a
building,
garage
or
enclosed
area.
All
LPG
supply/
piping
lines
must
be
installed
by
a
qualified
plumber.
If
you
smell
gas,
close
off
all
gas
sources
and
contact
a
qualified
plumber
to
inspect
and
repair
the
LPG.
Prior
to
each
days
first
use
spray
a
soapy
water
solution
on
LPG
fuel
connections
to
check
for
leaks.
Never
use
a
gas
container,
LPG
connector
hose
or
LPG
cylinder
that
appears
to
be
damaged.
Do
not
connect
or
disconnect
the
LPG
source
in
an
enclosed
area.
LPG
is
heavier
than
air
and
can
accumulate
in
confined/
low
spaces
if
there
is
a
leak.
NOTICE
If
a
fuel
supply
connection
is
necessary
it
must
be
installed
in
accordance
with
all
local
codes
or
regulations,
or
in
the
absence
of
local
codes
or
regulations,
in
accordance
with
the
National
Fuel
Gas
Code
(NFPA
54/ANSI
2223.1)
and
CSA
B149.1
(Natural
Gas
and
Propane
Installation
Code].
as
applicable.If
possible
the
fuel
supply
connection
should
be
close
to
the
outdoor
operating
location.
This
will
reduce
the
cost
of
the
flexible
fuel
run.
An
approved
flexible
fuel
line
must
be
installed
between
the
generator
LPG
Hose
Connector
(Inlet)
and
the
fuel
supply
connection.In
no
case
should
this
information
be
interpreted
to
conflict
with
any
local,
state,
or
national
code.
If
in
doubt,
always
follow
local
codes.
lPG
Always
keep
the
LPG
cylinder
in
an
upright
position.
Use
only
DOT LPG
cylinders
in
vapor
service
with
type
1,
right
hand
ACME
threads.
Verify
the
re-qualification
date
on
the
cylinder
has
not
expired.
All
new
cylinders
must
be
purged
of
air
and
moisture
prior
to
filling.
The
purging
process
should
be
done
by
your
propane
gas
supplier.
Attach
the
LPG
regulator
hose
assembly
(included)
to
the
LPG
hose
connector
(inlet)
on
the
control
panel
of
the
generator.
Tighten
the
nut
with
a
19
mm
or
adjustable
wrench.
Remove
the
safety
plug
or
cap
from
the
LPG
cylinder
valve.
Attach
the
LPG
regulator
to
the
cylinder
valve.
Do
not
use
a
wrench
to
tighten
LPG
cylinder
nut.
Tighten
the
nut
by
hand
clockwise
to
a
positive
stop.
Using
a
wrench
may
damage
LPG
cylinder
components.
English
16
Customer
Service 1-844-FIRMAN1