EasyManua.ls Logo

Firman WH03342 - WH03342_Manual_English _Page_28

Firman WH03342
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
Low
Oil
Shutdown
If
the
engine
oil
drops
below
a
preset
level,
an
oil
switch
will
stop
the
engine.
Check
oil
level
with
dipstick.
If
oil
level
is
between
the
LOW
and
HICH
mark
on
dipstick:
l.DO
NOT
try
to
restart
the
engine.
2.Contactan
Authorized
FIRMAN
Service
Dealer.
3.DO NOT
operate
engine
until
oil
level
is
corrected.
If
oil
level
is
below
the
LOW
mark
on
dipstick:
l.Add
oil
to
bring
level
to
HICH
mark.
2.Resta
rt
engine
and
if
the
engine
stops
again
a
low
oil
condition
may
still
exist.
DO
NOT
try
to
res
ta
rt
the
engine.
3.Contact
an
Authorized
FIRMAN
Service
Dealer.
4.DO
NOT
operate
engine
until
oil
level
is
corrected.
Do
Not
Overload
Generator
Overloading
a
generator
in
excess
of
its
rated
wattage
capacity
can
result
in
damage
to
the
generator
and
to
connected
electrical
devices.
To
prolong
the
life
of
your
generator
and
attached
devices,
follow
these
steps
to
add
electrical
load:
l.
Start
the
generator
with
no
electrical
load
attached.
2.
Allow
the
engine
to
run
for
several
minutes
to
stabilize.
3.
Plug
in
and
turn
on
the
first
item.
It
is
best
to
attach
the
item
with
the
largest
load
first.
4.
Allow
the
engine
to
stabilize.
5.
Plug
in
and
turn
on
the
next
item.
6.
Allow
thee
ngine
to
stabilize.
7.
Repeat
steps
5-6
for
each
additional
item.
Overload
Operation
The
overload
indicator
light
will
blink
when
the
load
exceeds
3550W(approximately)
and
cut
power
to
the
receptacles
in
30
seconds.
If
the
load
exceeds
3680W(approximately).
the
light
will
turn
on
and
cut
power
to
the
receptacles
in
2
seconds.
How
to
Correct
1.
Disconnect
any
electrical
devices,
and
then
stop
the
engine.
2.
Reduce
the
total
wattage
of
connected
electrical
devices
until
it
is
within
the
generator's
rated
output.
3.
Inspect
the
Air
Inlet
and
Control
Panel
for
any
blockage.
Remove
blockage
if
found.
4.
Restart
Engine.
Parallel
Operation
Any
two
Fl
RMAN
inverter
generators
with
para I lel ports,
including
two
Fl
RMAN
inverters
model
WH03342
can
be
paralleled
to
increase
the
total
available
electrical
power
to
6000
Watts.
A FIRMAN Parallel
kit
(not
included)
is required
for
parallel
operation.
For
Kit
availability, call
customer
Service
at
1-844-
347-6261
or
visit:
www.firmanpowerequipment.com.
English 26
Customer
Service 1-844-FIRMAN1

Table of Contents