OPERATION
12.
For
recoil
start
only-
PULL-TO-RUN
Pull
the
starter
cord
slowly
until
resistance
if
felt
and
pull
rapidly
to
run
the
portable
generator.
If
the
engine
fails
to
start
in
1-2
pulls
with
choke
in
the
RUN
position,
move
choke
knob
to
START
position
and
repeat
the
PULL-TO-PRIME
step
(10).
13.
For
electric
start
only-Flip
the
engine
switch
to
the
START
(11)
position
for
a
few
seconds
and
then
release.
II
~
14.
For
electric
start
only
-
Move
the
choke
knob
to
the
RUN
position.
15.
Al
low
portable
generator
to
run
at
no
load
for
a
few
minutes
to
stabilize
before
plugging
in
any
electrica
I
devices.
NOTICE
If
engine
starts
but
fails
to
run,
orif
portable
generator
shuts
down
during
operation,
check
oil
level.
See
Low
Oil
Shutdown
section
for
more
information.
NOTICE
Observing
frost
on
LPG
cylinder
and
regulator
is
common
during
operation
and
normally
is
not
an
indication
of
a
problem.
In
unusual
situations
this
frost
may
eventually
restrict
the
flow
of
LPG
gas
to
the
generator
resulting
in
deteriorating
performance.
In
these
rare
situations
it
can
be
helpful
to:
Exchanging
fuel
cylinders
to
allow
the
first
cylinder
to
warm
up,
repeating
as
necessary.
Placing
the
LPG
cylinder
at
the
end
of
the
generator
near
the
handle,
where
engine
fan
airflows
out
from
the
generator.
This
air
is
slightly
heated
by
air
flowing
over
the
engine.
Do
not
place
the
LPG
cylinder
in
the
path
of
the
muffler
exhaust
outlet.
The
LPG
cylinder
and
components
can
be
temporarily
warmed
by
pouring
warm
water
over
them.
English
21
Customer
Service 1-844-FIRMAN1