The Panda Generator
11.3.11 Panda_8000NE-10000NE_PMS_eng.R02 - Kapitel/Chapter 4: The Panda Generator Seite/Page 49
4.3.5 The Operation Surveillance System
Fig. 4.3.5-1: Thermo-switch at Cylinder Head
Thermo-switch at cylinder head
The thermo-switch at the cylinder head serves to monitor the
generator temperature. All thermo-switches for the genera-
tors from Panda 6.000 upward are two-pole (earthed), so cal-
led "openers". This means the contacts are open in normal
cases and close only when the limits have been exceeded.
Fig. 4.3.5-2: Thermo-switch at water-cooled exhaust elbow
Thermo-switch at water-cooled exhaust elbow
This Thermo switch is located at the water-cooled exhaust
elbow and serves to monitor the freshwater circulation
system. It takes a measurement at the warmest spot, since
the combustion gases are guided from the cylinder head to
the exhaust elbow.
Fig. 4.3.5-3: Thermo-switch at exhaust connection
Thermo-switch at exhaust connection
If the impeller pump stops and delivers no more seawater,
the exhaust connection becomes extremely hot.