Panda_5000i_PMS_eng.R01 9.12.10
Fischer Panda GmbH
Power - wherever you are
Generator manual
Panda 5000i PMS
Super silent technology
230V 50Hz 5kVA
120V 60Hz 5kVA

Table of Contents

Questions and Answers

  • C
    Christine WilliamsAug 13, 2025
    Why is my Fischer Panda Portable Generator producing sooty, black exhaust?
    • C
      Christopher CooperAug 13, 2025
      If the Fischer Panda Portable Generator produces sooty, black exhaust, it could be due to several reasons. The generator might be overloaded, so try reducing the electrical load by switching off unnecessary devices. It could also be caused by insufficient intake air, so check the intake air filter and clean it if necessary. Other potential causes include a faulty fuel injector (which would need replacing), incorrect valve clearance (which requires readjustment), poor fuel quality (use 2-D Diesel), or poor combustion due to incorrect air/fuel ratio (have the motor serviced by Kubota).
  • N
    Nicholas MorganAug 17, 2025
    Why does my Fischer Panda Portable Generator motor stop by itself?
    • L
      Lisa PettyAug 17, 2025
      If the Fischer Panda Portable Generator motor stops by itself, it could be due to a few reasons. Check the fuel supply system to ensure there's enough fuel. Also, check the cooling water system flow (water pump, inlet water filter, extra heat exchanger coolant flow) in case of excess heat. Additionally, verify the oil level and top up if necessary; if the oil pressure is low, have it repaired by Kubota-Service.
  • C
    Curtis HernandezAug 21, 2025
    What to do if the starter is turning motor, but it fails to start on my Fischer Panda Portable Generator?
    • L
      Lauren ParkerAug 21, 2025
      If the starter is turning the motor but it fails to start in your Fischer Panda Portable Generator, it could be due to several reasons. Check the wire connections and circuitry to the fuel stop solenoid valve. Inspect the fuel filter and pump, and clean if necessary. Ensure there is enough fuel supply. Check the glow plugs and heating time. Test the fuel system for leakage and bleed air from the fuel system. Replace the fuel filter if it's blocked.
  • A
    Aaron MillerAug 25, 2025
    Why doesn't the motor achieve enough speed during starting of my Fischer Panda 5000i PMS Portable Generator?
    • B
      Brittany ReyesAug 25, 2025
      If the motor does not achieve enough speed during starting process in your Fischer Panda Portable Generator, check the battery. If the battery voltage is insufficient, this could be the cause. Damaged bearings or a seized piston could also be the cause, requiring repairs by Kubota-Service. Another potential cause is cooling water in the combustion chamber. To resolve this: 1. Turn the generator "OFF" at the control panel. 2. Remove the glow plug. 3. Rotate the motor by hand carefully. 4. Check for water in the oil and change both the oil and filter if needed. 5. Determine the cause of excess water in the combustion chamber, such as a defective air vent in the cooling water system, which should be checked, cleaned, or replaced.
  • V
    victorbarnettAug 28, 2025
    How to fix low output voltage on a Fischer Panda 5000i PMS Portable Generator?
    • S
      Sharon NguyenAug 28, 2025
      If the Fischer Panda Portable Generator output voltage is too low, it could be because the PGMi is overloaded. Try reducing the electrical load by switching off some devices. Alternatively, the motor might not be reaching the rated RPM, so refer to the "motor faults" section.
  • B
    brittanyibarraSep 1, 2025
    Why does my Fischer Panda 5000i PMS Portable Generator motor run unsteady?
    • T
      Timothy MartinSep 1, 2025
      If the Fischer Panda Portable Generator motor runs unsteady, it may be due to a disruption in the area of the injection systems’ automatic advance, which requires a motor service to check and repair. It could also be caused by air in the fuel system, in which case you should ventilate the fuel system.
  • M
    Michael BakerSep 4, 2025
    What causes the Fischer Panda 5000i PMS motor speed to drop?
    • H
      Heather WashingtonSep 5, 2025
      If the Fischer Panda Portable Generator motor speed drops, check the fuel supply system. Ensure the fuel filter is clean (renew if necessary), check the fuel pump, and inspect the fuel lines, bleeding them if necessary.
  • D
    Daniel MaciasSep 8, 2025
    Why does my Fischer Panda 5000i PMS Portable Generator motor run in off position?
    • J
      Jacob WoodSep 8, 2025
      If the Fischer Panda Portable Generator motor runs in the off position, the fuel inlet solenoid valve or throttle shut solenoid may not be switching off. Check the wire connections to the solenoid and the valve functions, replacing if necessary.

Summary

General References and Regulations

Fischer Panda Company Overview

History and product development of Fischer Panda generators.

Safety Symbols and Warnings

Required Tools for Maintenance and Installation

Customer Registration and Warranty Information

General Safety Instructions

Safe Operation Practices

Guidelines for safe operation, including reading the manual and understanding limitations.

Personal Protective Equipment (PPE)

Mandatory PPE for safe operation and maintenance, including clothing, eye, and hand protection.

Maintaining a Clean Environment

Importance of keeping the generator and surroundings clean to prevent hazards.

Hazardous Materials and Fire Prevention

Specific Safety Precautions

Security, Labels, and Operating Safety

Electrical Safety and Load Management

Cable and Battery Installation Safety

Battery Handling and Safety

Emergency First Aid Procedures

First Aid for Respiratory Arrest

Instructions for cardiopulmonary resuscitation (CPR) and rescue breathing on an adult.

Basics of Generator Operation

Intended Use and Product Description

Defines the generator's purpose, how it works, and safety notes regarding its application.

Manual Definitions and Personnel Roles

Explains terms like 'trained person', 'operator', and 'user' and their responsibilities.

Panda Transport Box Procedures

Generator Transport and Handling

Extended Downtime and Storage Procedures

Instructions for Starter Battery During Downtime

Guidance on managing the starter battery during extended periods of generator inactivity.

Measures for Short Downtimes

Specific procedures for generators that will be inactive for short periods (1-3 months).

Medium-Term Downtime Preparations

Surface Protection Measures for Medium Downtime

Applying protective measures to the generator for medium-term storage (3-6 months).

Recommissioning After Medium Downtime

Steps to remove protective measures and recommission after medium-term downtime.

Extended Downtime and Decommissioning

Surface Protection for Extended Downtime

Applying protective measures to the generator for extended storage (over 6 months).

Recommissioning After Extended Downtime

Steps to remove protective measures and recommission after extended downtime.

Generator Components Overview

Generator Range of Operation and Features

Panda 5000 i PMS Generator Details

Generator Type Plate Information

Details and description of the generator's type plate.

Generator Description and Views

Generator Right Side View

Detailed view and identification of components on the right side of the generator.

Generator Left Side View

Generator Front View

Generator Back View

Generator Top View

Generator Function Unit Details

iControl Panel Reference

Reference to the iControl manual for details on the remote control panel.

Raw Water Cooling System Components

Diagram and description of the components within the raw water cooling system.

Freshwater Cooling System Components

Fuel System Components

Combustion Air System Components

Electrical System Components

Oil Circuit and Monitoring Systems

Oil Circuit Components

Description of the components within the generator's oil circuit.

Operating Surveillance Sensors

Details on sensors and switches used for monitoring generator operation.

Engine Monitoring Sensors

Generator Operation via iControl

Generator Installation Instructions

Personnel Requirements and Installation Safety

Prerequisites for personnel and general safety guidelines for generator installation.

Installation Hazard Notes and Precautions

Generator Placement and Sound Insulation

Generator Electrical Connections

Instructions for making secure electrical connections for the generator.

Raw Water Cooling System Installation

General references and instructions for installing the raw water cooling system.

Raw Water Intake Installation Details

Below Waterline Raw Water Installation

Freshwater Cooling Circuit Setup

Coolant Filling and De-aeration

Watercooled Exhaust System Installation

Instructions for installing the watercooled exhaust system and its components.

Water Collector Installation and Risks

Exhaust System Troubleshooting and Collector Placement

Exhaust Water Collector Sizing

Optimal Water Collector Positioning

Water Collector Positioning Under Tilt

Off-Center Water Collector Installation Examples

Off-Center Collector Tilt Analysis

Exhaust Water Separator System

Exhaust Water Separator Installation

Fuel System Installation Guide

General Fuel System Installation References

General references and components required for the installation of the fuel system.

Fuel Pump and Tank Connections

Fuel System Pre-filter and Venting

Generator DC System Installation

Starter Battery Block Connection

Instructions for connecting the starter battery block to the generator's DC system.

Starter Battery Connection and Safety

Generator AC System Installation

Inverter and Power Source Selector Installation

AC System Components and Safety

Electrical System Insulation Testing

Generator Maintenance Instructions

Personnel Requirements for Maintenance

Specifies the qualifications required for performing maintenance tasks.

Maintenance Hazard Notes

Important safety warnings and precautions related to generator maintenance.

General Maintenance Procedures

Pre-Start and Monthly Checks

Routine checks to perform before each start and monthly maintenance tasks.

Hose and Rubber Part Inspection

Inspection of hoses and rubber parts in the sound insulated capsule for wear.

Engine Oil Change Intervals

Schedule for engine oil changes based on operating hours.

Checking Engine Oil Level

Refilling Engine Oil

Engine Oil and Filter Exchange

Oil and Filter Exchange Procedure

Post Oil Change Procedures and Disposal

Starter Battery Verification

Battery and Cable Connection Check

Checking battery cleanliness, terminal connections, and cable integrity.

Electrolyte Level Check

Procedure for checking the electrolyte level in the battery cells.

Electrolyte Density Check

Fuel Supply Water Separator and Filter

Fuel Filter Exchange

Guidelines for exchanging the fuel filter based on contamination and operating hours.

Optional Fuel Filter Maintenance

Fuel System Venting Procedure

Air Filter Replacement

Coolant and Raw Water Systems

Coolant Circuit De-aeration

Procedure for de-aerating the freshwater coolant circuit.

Raw Water Filter Cleaning

Instructions for cleaning the raw water filter to ensure proper flow.

Raw Water Pump Impeller Issues

Analysis of causes for frequent impeller wear in the cooling water pump.

Impeller Replacement Procedure

Generator Faults and Troubleshooting

Personnel Requirements for Fault Finding

Specifies the qualifications required for diagnosing generator faults.

Fault Finding Hazard Notes

Important safety warnings and precautions related to troubleshooting generator faults.

Troubleshooting Tools and Common Issues

Tools and Measuring Instruments

List of tools and measuring instruments for managing generator disturbances.

Generator Overloading

Guidance on preventing generator overloading and its consequences.

Starting Problems Overview

Common issues that can prevent the generator from starting.

Fuel Filter and Voltage Troubleshooting

Fuel Solenoid Valve Issues

Troubleshooting the fuel solenoid valve for starting problems.

Dirty Fuel Filter

Addressing issues caused by a dirty fuel filter.

Low Generator Output Voltage

Troubleshooting steps for low output voltage in 50 Hz versions.

Engine Starting and Running Faults

Generator Operation and Shutdown Faults

Generator Technical Data and Tables

Cable Cross Section Tables

Tables detailing recommended cable cross-sections for various lengths and currents.

Conduit Diameter Specifications

Specifications for the diameter of conduits used in the generator system.

Generator Technical Data Summary

Summary of key technical data for the Panda 5000i PMS generator.

Engine Oil Specifications

Engine Oil Classification and Operating Range

Classification of engine oils by SAE class and operating temperature range.

Engine Oil Quality Standards

API standards for engine oil quality applicable to diesel engines.

Fuel and Coolant Specifications

Coolant Mixture Ratios

Generator Dimensions

Panda iControl Remote Control Panel

iControl Panel Safety and Connection

Safety precautions and detailed instructions for connecting the iControl panel using the prepared cable.

iControl Panel Interface and Controls

iControl Panel Additional Information Screen

iControl Operation Manual and Checks

General iControl Operation and Winter Tips

Generator Start, Stop, and Automatic Start

iControl Error Warnings

iControl Errors and Electronic Board

Electronic Board Location

Technical Data and Bus Adapter

Inverter Panda PMGi 5000 Datasheet

PMGi 5000 Inverter Safety and Type Plate

Safety instructions for the inverter and information on locating its type plate.

PMGi 5000 Inverter Type Plate Details

PMGi 5000 Inverter Front and Connection Side

PMGi 5000 Inverter Socket Pinouts

PMGi 5000 Inverter Back Side Details

PMGi 5000 Inverter Operation and Status

PMGi 5000 Inverter Installation and Technical Data

PMGi 5000 Inverter Output and Protections

Fischer Panda 5000i PMS Specifications