Inverter Panda PMGi 5000
Seite 128 - Kapitel 10: Inverter Panda PMGi 5000 PGMi 5000_eng.fm
Fischer Panda Datenblatt / Datasheet
10.4 Back side - Top side
Fig. 10.4-1: Back side
Inside of the PMGi a fan is mounted. The air holes and air grille should not be covered.
01. Air holes
Attention!
Inside of the PMGi are up to 550VAC. The cover of the PMGi
should only be opened by special trained persons !!! Danger
for Live“
Attention!
Make sure that the connection between the generater and the
PMGi is secured. Never connect or disconnect the PMGi while
the generator is running. This will destroy the PMGi (it may
burn or explode).