Loading...
Basics
Seite/Page 36 Panda_5000i_PMS_eng.R01 - Kapitel/Chapter 3: Basics 9.12.10
Attention!
Before recommissioning, remove preservatives and protective
measures.
3.4.4.2 Measures for removing surface protection after extended downtimes /
recommissioning (over 6 months):
Check battery charge status and recharge if necessary. Observe instructions of the battery manufacturer.
Check cooling water anti-freeze level and cooling water level and refill as necessary.
Drain engine oil. Replace oil filter and oil as per the specification.
Remove preservatives from the engine with petroleum spirit.
Degrease V-belt disks and mount V-belt according to instructions. Check V-belt tension!
If applicable, open turbocharger oil pressure line and fill clean engine oil into channel.
Hold engine stop lever in zero delivery position and crank engine manually several times.
Clean air filter housing with petroleum spirit, check air filter and replace if necessary.
Remove covers from exhaust aperture and intake apertures.
Connect battery. Close battery main switch.
Hold stop lever on generator motor in neutral position and crank starter for approx. 10 seconds. Then, pause for 10
seconds. Repeat this procedure 2 times.
Perform visual check of the generator similar to initial commissioning and start up generator.
Note:
Fischer Panda recommends:
After extended downtimes, a full 150 h inspection as per the
inspection list should be performed.
3.5 Components
Fig. 3.5-1: Panda 5000i generator
1. Panda i-Generator Permanent-Magnet-Generator

Table of Contents