Remote control panel Panda iControl
Panel_iControl_eng_modi.fm Kapitel 9: Remote control panel Panda iControl - Seite 115
Fischer Panda Datenblatt / Datasheet
9.4 Engine control
The iControl Panel and Electronic Board is for driving the Panda i-series generator. Push the „on/off“ button to start
the panel(1). The panel will come up in the „stand by mode“.
„stand by mode“
in the stand by mode the iControl checks the generator
• Display shows welcome screen
• the Led-Light will switch off after 2 min. (energie save)
• push the „enter“ button“ to reset the LED-Light timer
• start the generator with the „start/stop“ button --> „run mode“
• start the generator with the „automatic start“ option --> „run mode“
„run mode“
Generator was started with the “start/stop“ button or with the „automatic start option“
• Display light is on
• Display shows generator data
• stop the generator with the „start/stop“ button --> „standby mode“
• stop the generator with the „automatic start“ option --> „standby mode“
9.5 Operation manual
9.5.1 Daily routine checks before starting
1. Oil Level Control (ideal level: 2/3 of maximum).
ATTENTION!
OIL PRESSURE CONTROL!
True, the diesel motor automatically switches off when there is
a lack of oil, but it is very damaging for the motor, if the oil level
drops to the lowest limit. Air can be sucked in suddenly when
the boat rocks in heavy seas, if the oil level is at a minimum.
This affects the grease in the bearings. It is therefore neces-
sary to check the oil level daily before initially running the
generator. The oil level must be topped up to the 2/3 of maxi-
mum level, if the level drops min. mark.
2. State of cooling water.
The external compensation tank should be filled up to a 1/3 level of in a cold state. It is very important that large
expansion area remains above the cooling water level.
3. Open sea cock for cooling water intake.(if necessary)
For safety reasons, the seacock should be closed after the generator is switched off for a longer time. It should
be re-opened before starting the generator.
4. Check raw water filter.
The raw water filter must be regularly checked and cleaned. The impeller fatigue increases, if residual affects the
raw water intake.
5. Check all hose connections and hose clamps are leakage.
Leaks at hose connections must be immediately repaired, especially the raw water impeller pump. It is certainly
possible that the raw water impeller pump will produce leaks, depending upon the situation. (This can be caused