Generator Faults
Seite/Page 104 Panda_5000i_PMS_eng.R01 - Kapitel/Chapter 7: Generator Faults 9.12.10
7.6.7 Motor runs in off position
7.6.8 Motor stops by itself
7.6.9 Sooty, black exhaust
7.6.10 Generator must be shut off immediately if:
Lack of intake air. Check air intake paths.
Check and clean air filter (and intake muffler if installed).
Generator overloaded by too many load. Reduce the electrical load (switch off load).
Defective generator (windings, bearings, or other). Generator must be sent to manufacturer for repair of damaged bearings
or winding.
Damaged engine. Repair of bearing damage, etc., by Kubota-Service.
Cause Solution
Fuel inlet solenoid valve or throttle shut solenoid is not switching off. Check wire connections to solenoid. Check valve functions as in the
"Fuel Solenoid Valve" or in the trottle shut off solenoid sections. Replace
if necessary.
Cause Solution
Lack of fuel. Check fuel supply system.
Excess heat in cooling system (thermo switch tripped)-lack of cooling
water. Is indicated on the remote control panel.
Check cooling water system flow: water pump, inlet water filter, extra
heat exchanger coolant flow.
Lack of oil (oil pressure sensor tripped). Is indicated on the remote con-
trol panel.
Check oil-level and if necessary top up.
Check motor's oil-pressure and have repaired by Kubota-Service if ne-
cessary.
Cause Solution
Generator is overloaded. Check electrical load and switch off unnecessary load.
Insufficient intake air. Check intake air filter; clean if necessary.
Fuel injector faulty. Replace injector.
Valve clearance incorrect. Readjust valve clearance to correct value (refer to Farymann-manual).
Poor fuel quality. Use better quality diesel (recommended: 2-D Diesel).
Poor combustion. Incorrect AFR (air/fuel ratio) due to motor timing adjustment. Have motor
serviced by Kubota.
Cause Solution
- motor rpm suddenly rises or drops
- unusual noise comes from genset
- exhaust colour suddenly becomes dark
- leakage in the cooling water system.
Refer to respective section of manual and if necessary, have repaired by
Kubota-Service, or Panda representative.
Cause Solution