Seite 112 - Kapitel 9: Remote control panel Panda iControl Panel_iControl_eng_modi.fm
Fischer Panda Datenblatt / Datasheet
9.1 Safety instructions
The generator may not be taken into use with the
cover removed.
The rotating parts (belt-pulley, belts, etc) must be covered
and protected so that there is no danger to life and body!
If a sound insulation cover must be produced at the place of
installation, then well-placed signs must show that the gener-
ator can only be switched on with a closed capsule.
All servicing-, maintenance or repair work may only be car-
ried out, when the motor is not running.
Electrical power:
DANGER TO LIVE!
Electrical voltages above 48 volts (battery chargers greater
than 36 volts) are always dangerous to life). The rules of the
respective regional authority must be adhered to. Only an elec-
trician may carry out installation of the electrical connections
for safety reasons.
Before start working at the Panda i-series generator (service, repair ect), diconnect the starter battery (First minus
cable, then positive cable), so that the generator cannot be unintentionally started.
9.2 Connection of the iControl
Fig. 9.2-1: iControl back side
To connect the iConrol use the original prepared cable.
(6 wires shilded)
Between clamp RZL(3) und Gnd(2) an automatik start device (Battery monitor) can be connected
Note
Regarding to the open electric board the iControl panel has a
protectrive class IP00.
Builded in a control board with a siutable seal (f.e. Sikaflex)
IP66 can be reached.