7.2.14 Removal of Water Valves
1. Follow procedure for removal of table top (refer
to Section 7.2.1).
2. Remove harness connections to water valve.
3. Release the hose clamps and the remove the
hoses.
4. Undo the mounting screws and remove valve.
Reassemble in the reverse order
7.2.15 Removal of the Heater
1. Remove harness connections from the element,
earth and the NTC terminals.
2. Undo the nut securing the element assembly to
the tub then slide the heater out of the tub.
Reassemble in the reverse order; ensuring that the
heater is correctly located as it must sit in the
retainer inside the tub.