479646
8
2.10 Water Inlet Valves
Cold Valve dual type.
Hot valve single type.
220V – 240V AC 50Hz.
Resistance 4 KΩ +/- 5%.
Cold maximum inlet temperature 35
O
C.
Hot maximum inlet temperature 65
O
C.
2.11 Pressure Sensor
The machine is fitted with a pressure sensor, which controls the fill to any water level. The pressure sensor
is a stand alone component which is replaceable and is connected to the tub air chamber via the pressure
tube.
2.12 Drain Pump
220V – 240V AC 50Hz.
Total power 30W.
Resistance 212 Ω.
Pump out rate 15litres/min.
Overheat protection thermal link 105
O
C.
2.13 Door Lock
Type Solenoid Activated.
With mechanical release.
Resistance Terminal 2 & 3 190Ω 10%.
Nominal Voltage Terminal 2&3 230V.
2.14 Flood Protection
Pressure sensor activated.
The drain pump will run when pressure switch is activated and fault code 12 will be displayed.
2.15 Motor EMI Filter
Inductor – 7.8mH
2.16 EMI Filter Capacitor
X Capacitor 0.47uF
Y Capacitor 470nF
L Inductor > 4mH