479646
8
2.10 Water Inlet Valves
Cold Valve dual type.
Hot valve single type.
220V 240V AC 50Hz.
Resistance 4 K +/- 5%.
Cold maximum inlet temperature 35
O
C.
Hot maximum inlet temperature 65
O
C.
2.11 Pressure Sensor
The machine is fitted with a pressure sensor, which controls the fill to any water level. The pressure sensor
is a stand alone component which is replaceable and is connected to the tub air chamber via the pressure
tube.
2.12 Drain Pump
220V 240V AC 50Hz.
Total power 30W.
Resistance 212 .
Pump out rate 15litres/min.
Overheat protection thermal link 105
O
C.
2.13 Door Lock
Type Solenoid Activated.
With mechanical release.
Resistance Terminal 2 & 3 190 10%.
Nominal Voltage Terminal 2&3 230V.
2.14 Flood Protection
Pressure sensor activated.
The drain pump will run when pressure switch is activated and fault code 12 will be displayed.
2.15 Motor EMI Filter
Inductor 7.8mH
2.16 EMI Filter Capacitor
X Capacitor 0.47uF
Y Capacitor 470nF
L Inductor > 4mH