TROUBLESHOOTING GUIDE
SYMPTOM              CAUSE                      SOLUTION
Detector chatters,       • Using detector            • Use detector
beeps erratically  indoors   outdoors only
or has low                   • Using detector near    • Move away 
sensitivity   power lines                 
from power lines
                                   • Using 2 detectors        • Keep 2 detectors
  in close    at least  6 meters
  proximity  (20’) apart
                                   • Environmental            • Reduce sensitivity
  electromagnetic   until erratic
  interference  signals cease
Low speaker               • 
Discharged battery
      • Replace battery
volume
                        • Wrong type of             • Use only 9Volt  
  battery  alkaline battery
   
Display does not lock
  • Multiple targets           • 
Sweep searchcoil at
on to one Target-ID  present  different angles
or detector emits         • Highly mineralized     • Move to a  
multiple tones  soil   different location
 
• Sensitivity set
 
• Reduce sensitivity
  too high  
No power, no sounds
  • Dead battery               • Replace battery
 
• Cable not                    • 
Check connections
  connected securely 
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection
against  harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses  and  can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television  reception,  which  can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Consult the dealer or an experienced radio/TV technician for help.
CE
   The manufacturer declares that the minimum ESD performance criteria is 1) the unit shall not 
         be permanently damaged and 2) operator intervention is allowed.
This product is RoHS compliant.
This product meets the requirements of Industry Canada: CAN ICES-3 B/NMB-3 B.